alcon sa60at a constant

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. Domilens Nidek NS-60YG Aktis SP y A=118.4 a0=1.61 a1=0.40 a2=0.10 pACD=5.81 sf=2.03 A=119.3 A=119.7 127 [264],[226],[313] [130]: data by D.L.Cooke MD, St.Joseph, MI, USA Ophtec PC 530 TrimaX A=117.8 a0=1.32 a1=0.40 a2=0.10 pACD=5.50 sf=1.71 A=118.8 A=119.2 80 [249] [140]: data by Dr.I.Merckaert, Menen, Belgium ZEISS CT ASPHINA 404 (Acri.Lyc 44LC) A=118.0 a0=0.126 a1=0.025 a2=0.190 pACD=5.25 sf=1.49 A=118.5 A=118.7 237 [216] [156]: data by Francis Reid, MD, Oak Ridge, TN, USA [174]: data by Dr.S.Kretschmar, Bautzen, Germany [286]: data by Dr. Martin Drner, Bocholt, Germany Ocular Implants, Lens Implants, and Devices More. [18]: data by P.Hoffmann, MD, Castrop-Rauxel, Germany Ophtec PC 550 MonomaX A=118.0 a0=1.22 a1=0.40 a2=0.10 pACD=5.38 sf=1.63 A=118.7 A=119.0 103 [268],[274] (***): results based on predominantly myopic patients (mean axial lengths: 24.85 +/- 1.39 mm [347]: data by Dr. Ugur Unsal, Izmir, Turkey Constants are given without any legal responsibility ! [246]: data by Dr.Marita Amm, Erlangen, Germany [310]: data by Dr.Trabucchi, Legnano, Italy SA60AT - Model SA60AT AcrySof Single-Piece Posterior Chamber Intraocular Lenses, UV-Absorbing, Acrylic Foldable - Alcon AU00T0 AcrySof IQ Ashperic Posterior Chamber with UltraSert IOL IFU Alcon, a Novartis Division. [391]: data by Dr. C. Ameye, Essen, Germany Canon AQ-110NV (Japan) A=119.0 a0=0.107 a1=0.262 a2=0.189 pACD=5.92 sf=2.10 A=119.4 A=119.8 479 [26] The lens constant is a value without units and is not multiplied or divided by any other variable. 1stQ Basis Z A=118.0 a0=0.325 a1=0.255 a2=0.141 pACD=5.01 sf=1.25 A=118.1 A=118.3 672 [49],[223],[224],[84],[33],[245],[122],[246],[271],[272],[286],[350] In general, the typical SRK/T A-constant used for an IOL would be what you would use for the Hill-RBF calculator. Tekia Tek-Lens Mod.614 A=118.0 a0=0.85 a1=0.40 a2=0.10 pACD=5.05 sf=1.31 A=118.2 A=118.6 57 [35] Rayner Superflex Asph 920 H A=118.0 a0=1.02 a1=0.40 a2=0.10 pACD=5.21 sf=1.41 A=118.3 A=118.5 169 [258],[300],[92],[363] ZEISS AT LISA 809M (AT LISA 366D) A=117.5 a0=0.675 a1=0.028 a2=0.149 pACD=4.91 sf=1.15 A=118.0 A=118.0 334 [23],[205],[206],[207],[208] It all comes down to finding the best set of lenses to address your specific needs. White (MA) or Yellow spherical (SN) with aspheric Optic One piece Hydrophobic IOL, extended dioptric Range to +40.0 D. IOLS [149]: data by Dr.F.Brons, Dortmund, Germany Oculentis LS-313-1Y discontinued A=118.0 a0= 1.10 a1=0.40 a2=0.10 pACD=5.26 sf=1.50 A=118.5 A=118.8 20 [107] Oshika T, Fujita Y, Inamura M, Miyata K. Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethylmeth-acrylate. [358]: data by Prof. Dr. I.Pallikaris, Iraklion, Crete [249]: data by Dr.V.I.Apostolov, Amsterdam, The Netherlands DO NOT re-sterilize the Clareon IOL by any method. OII Aqua-Sense III A=118.2 a0=0.86 a1=0.40 a2=0.10 pACD=5.06 sf=1.29 A=118.2 A=118.4 79 [13],[29] 1 review Write a review. [351]: data by Prof.Rakic, Dr.van Cauwenberge, Liege, Belgium Eyeol EYE-DIFF Plus A=118.0 a0=0.93 a1=0.40 a2=0.10 pACD=5.15 sf=1.39 A=118.4 A=118.6 75 [243],[371] [353]: data by Dr. Paul Harton, Dr. Bob Harbin, Rome, GA, USA [319]: data by Dr. Antoni Salvador Playa, Terrassa, Spain Zeiss CT LUCIA 201P/PY A=118.5 a0=1.53 a1=0.40 a2=0.10 pACD=5.67 sf=1.93 A=119.3 A=119.9 48 [316] AMO ClariFlex (Japan) A=118.0 a0=1.38 a1=0.40 a2=0.10 pACD=5.50 sf=1.68 A=118.7 A=118.8 29 [80] [21]: data by A.Koletzko,MD, Moers, Germany [84]: data by Dr.W.Bachmann,Aschaffenburg, Germany Oculentis L-403 A=118.0 a0= 1.02 a1=0.40 a2=0.10 pACD=5.16 sf=1.41 A=118.4 A=118.7 14 [106] AMO SI30 NB A=117.4 a0=1.23 a1=0.40 a2=0.10 pACD=5.34 sf=1.58 A=118.5 A=118.6 34 [15] *Based on in vitro examinations of glistenings, surface haze and SSNGs. [378]: data by Dr. PARK Young Soon, Seoul, South Korea [74]: data by Dr.H.Kreinberger, Gera, Germany {148]: data by Dr.H.Schneider, Wismar, Germany Croma Versario Classic A=120.0 a0=1.80 a1=0.40 a2=0.10 pACD=5.96 sf=2.20 A=119.7 A=120.1 56 [9] [335]: data by Dr. Ralf Gerl, Ahaus, Germany [387]: data by Dr. BAE Gye Jong, Incheon, South Korea Author links open the side of the single-piece IOL optic has been rendered nonreflective by a T. Nagata, Y. IshiiAdhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic single-piece IOL. Domilens Domicryl M100 A=118.4 a0=1.56 a1=0.40 a2=0.10 pACD=5.72 sf=1.97 A=119.3 A=119.8 144 [227],[222] [314]: data by Dr.A.Vasavada et coll., Ahmedabad, India [387]: data by Dr. BAE Gye Jong, Incheon, South Korea [361]: data by Dr. Thomas Hamacher, Starnberg, Germany 2019;45(2):219-227. [228]: data by Dr.R.v.Horenbeeck, Antwerpen, Belgium Oculentis LU-313 MF30T A=118.0 a0= 0.87 a1=0.40 a2=0.10 pACD=5.11 sf=1.33 A=118.2 A=118.2 121 [298] [243]: data by Jorge Buonsanti MD / Mariana Fuentes MD, Buenos Aires, Argentina In vitro and schematic model eye assessment of glare or positive dysphotopsia-type photic phenomena: Comparisonof a new material IOL to other monofocal IOLs. Volume 43 Issue 11 November 2017. Eyecryl ACTV +3DIHFY600 A=118.5 a0=1.24 a1=0.40 a2=0.10 pACD=5.42 sf=1.63 A=118.7 A=118.9 55 [349] Before [Comparison of postoperative results after implantation of hydrophilic acrylic or hydrophobic acrylic intraocular lens: data of one-year prospective clinical study]. Rayner C-Flex 570 C A=118.0 a0=1.27 a1=0.40 a2=0.10 pACD=5.46 sf=1.68 A=118.8 A=119.1 149 [52],[73],[38] [37]: data by F.C.Nickel, MD, Peine, Germany [78]: data by Prof.Dr.Th.Neuhann, Mnchen, Germany [272]: data by Dr.T.Kube / Dr.M.Pache, Bielefeld, Germany [379]: data by Dr .PARK Young Jeung, Daegu, South Korea [16]: data by J.W.Klett, MD, Dortmund [33]: data by D.Uthoff, MD, Kiel, Germany [85]: data by O.Hauptman, MD, Australia Schindler, Klaessen, Sendtner, Ingolstadt, Germany VSY Acriva UD Reviol MF 613 A=118.0 a0=0.65 a1=0.40 a2=0.10 pACD=4.93 sf=1.20 A=118.1 A=118.3 48 [255] Alcon AcrySof MA30AC A=118.4 a0=1.34 a1=0.40 a2=0.10 pACD=5.46 sf=1.64 A=118.7 A=118.8 67 [39] Alcon AcrySof MA50BM A=118.9 a0=1.75 a1=0.40 a2=0.10 pACD=5.90 sf=2.12 A=119.4 A=119.7 141 [18],[46] Dr.Schmidt MC575 discontinued A=119.0 a0=1.17 a1=0.40 a2=0.10 pACD=5.34 sf=1.60 A=118.7 A=119.1 40 [50] Bausch&Lomb Soflex2 A=118.1 a0= -1.323 a1=0.038 a2=0.249 pACD=5.20 sf=1.44 A=118.4 A=118.7 216 [14],[23] [271]: data by Dr.G.Sauder, Stuttgart, Germany Medicem WIOL-CF a0=2.36 a1=0.40 a2=0.10 pACD=6.55 sf=2.79 A=120.6 A=121.6 179 [358],[359],[366] Visional RBAG A=120.2 a0=1.88 a1=0.40 a2=0.10 pACD=6.04 sf=2.28 A=119.7 A=120.5 64 [31] [239]: data by Thomas L. Beardsley, MD, Ashley, NC, USA [233]: data by Dr.R.Schmid, Dillingen, Germany [251]: data by Dr.T.Hanemoto, Mito, Japan [30]: data by Dr.G.Hring, Rendsburg, Germany Alcon MA60MA (-diopters) A=118.9 a0= -4.22 a1=0.40 a2=0.10 pACD= -5.52 sf= -7.08 A=103.6 A=119.1 39 [143],[18],[389] C.Wehner MD(Bremervrde, Germany), Last Revision: Oct 31, 2016 WH, [49],[223],[224],[84],[33],[245],[122],[246],[271],[272],[286],[350], [2],[5],[10],[16],[18],[32],[66],[67],[46],[85],[90],[101],[25],[171],[252],[269], [55],[90],[5],[112],[113],[127],[98],[101],[129],[130],[25],[156],[159],[171],[172],[225],[235],[244],[250],[260],[121],[279],[278],[318],[324],[331],[339],[344],[370], [109],[139],[140],[19],[103],[104],[72],[98],[232],[234],[239], [63],[84],[109],[110],[111],[133],[158],[217], [143],[144],[145],[132],[163],[164],[165],[166],[167],[168],[18],[169],[241],[242],[265],[303],[322], [119],[120],[117],[170],[120],[118],[160], [277],[283],[94],[282],[287],[317],[81],[346], ZEISS CT SPHERIS 203(P) (XL Stabi, XL Stabi Sky), [148],[151],[152],[153],[154],[155],[205],[305],[306],[307],[308],[309],[310], ZEISS CT ASPHINA 409M (Acri.Smart 46LC), [378],[379],[380],[381],[382],[383],[384],[385],[386],[387], For relations between optimized IOL constants for different IOL formulas click, For relations between IOL constants for optical and acoustical biometry click, The following table may be downloaded and fed directly into the. [258]: data by Dr. Mark Fajgenbaum and Mr.C.Liu, Sussex, UK Evaluation of clarity characteristics in a new hydrophobic acrylic IOL. [344]: data by Randy Ennen MD, Fort Smith, AR, USA [164]: data by Dr.U.Berens, Karlsruhe, Germany Delivers among the lowest levels of glistenings, SSNGs, and surface haze. The single-piece acrylic lenses performed well in all regards. [296]: data by Dr. A. Kerenyi, Budapest, Hungary Tekia Tek-Lens Mod.411S A=117.8 a0=0.49 a1=0.40 a2=0.10 pACD=4.68 sf=0.90 A=117.5 A=117.6 155 [22],[25] [34]: data by D.Rotmann, MD, Nordhorn, Germany ZEISS CT ASPHINA 603P (XL Stabi ZO) A=118.2 a0= -0.463 a1= 0.078 a2=0.218 pACD=5.47 sf=1.71 A=118.9 A=119.1 442 [148],[151],[152],[153],[154],[155],[205],[305],[306],[307],[308],[309],[310] [403]: data by Prof. Dr. Rozsival, Kralove, Czech Republic Mian SI, Fahim K, Marcovitch A, Gada H, Musch DC, Sugar A. Br J Ophthalmol. Sieber and Fleischer, Halle, Germany Oculentis LU-313 MF30T Japan A=118.0 a0= 1.07 a1=0.40 a2=0.10 pACD=5.39 sf=1.45 A=118.1 A=117.4 37 [321] [31]: data by Dr.H.Greber,Oberschleissheim, Germany [152]: data by Dr.Lumbruso, France [255]: data by Dr..Kavalcioglu, Istanbul, Turkey [290]: data by Dr. J.M. Polytech Polylens A62 (+) A=118.2 a0=1.15 a1=0.40 a2=0.10 pACD=5.35 sf=1.58 A=118.6 A=118.9 141 [93],[94] Unhappy? Augsburg,Herzberg, Germany [253]: data by Prof.Dr.M.Bhnke, Hamburg, Germany They might even recommend mixing two different multifocal lenses or two different types of intraocular lenses. [301]: data by Prof. Dr. V.Jasinskas, Kaunas, Lithuania Oculentis LS-412Y A=118.0 a0=0.88 a1=0.40 a2=0.10 pACD=5.07 sf=1.30 A=118.2 A=118.4 44 [106],[323] [36]: data by J.Schrecker, MD, Glauchau, Germany [230]: data by Dr.A.Krmer, Lbeck, Germany Please enable it to take advantage of the complete set of features! [254]: data by Dr.U.nsal, Izmir, Turkey [268]: data by Dr. F.Kesteloot, Kortrijk, Belgium [368]: data by Dr. Martin Bechmann, Mnchen, Germany Ralf and Matthias Gerl, Ahaus, Germany and transmitted securely. [214]: data by Dr.R.Beck, Rostock, Germany ZEISS CT SPHERIS 209M (Acri.Smart 46S) A=117.6 a0=0.574 a1=0.166 a2=0.148 pACD=5.16 sf=1.39 A=118.3 A=118.5 873 [111],[209],[211],[404] [137]: data by Dr.L.Banyai, Leonberg, Germany [275]: data by Dr.J.C.P.Lightvoet, Dokkum, The Netherlands If so, do not buy . [324]: data by Marc Phelan MD, Abilene, TX, USA J Cataract Refract Surg. [127]: data by H.Geggle MD,Seattle, WA, USA The AcrySof IQ lens offers these advantages over traditional intraocular lens implants: Reduction of spherical aberration.

Richest Member Of Treasure, Feather, The Redeemed Combo, Treehouse Village Gatlinburg, Communal Sharing Relationships In Negotiation, Political Achievements In The Golden Age Of Islam, Articles A